The emergency call alarm systems for freezer rooms consist of a main unit, sirens, and up to 4 lighted trigger points. Emergency call equipment is communications equipment by means of which the necessary help can be summoned and sent to the place of use. Even in freezer rooms, emergencies can occur and risk to human life may arise.
Properties
Operations
The personnel emergency call is triggered by a palm button, which is available in two designs. The alarm is forwarded audibly via the sirens and visibly via a relay contact on the main unit. A flashing light for an additional optical alarm can be connected to the main unit. The palm buttons are lighted in case of darkness. Power is supplied from the main unit with an installed storage battery and charge controller. The function of the emergency call alarm system is thus guaranteed, even in case of a mains failure.
The personnel alarm can be extinguished by the employees themselves only by unlocking the palm buttons.
Main unit
Rated voltage: 230 V AC / 50 Hz
Alarm relay: Load: max. 1 A/cos phi = 1.0 / 24 V DC
Changeover contact of storage battery: NiMH, 12 V DC, 800 mAh
Alarm duration in case of mains failure with fully charged storage battery and 4 buttons, including 4 LED lamps, the siren, and the flashing light (not included in delivery): about 10 hours
Ambient temperature: 0 °C to +55 °C
Type of protection: IP54
Dimensions (W x H x D): 213 x 180 x 100 mm
Sirens
Voltage range: 9 - 15 V and 18 - 28 V DC
Current consumption: max. 32 mA / 12 V DC
Output: 103 dB(A) at DIN sound
Ambient temperature: -25 °C to +70 °C
Type of protection: IP65
Approval: VdS G206019
Dimensions: diameter 93 mm, height 91 mm
Palm buttons
Foot and large hand switch with mushroom button, self-locking, resettable by pulling, tamper-proof according to ISO 13850/EN 418, with illuminated indicator
Type of protection: IP67
Ambient temperature: -25 °C to +40 °C
Dimensions: 85 x 121 mm, mushroom button ø94, height 101 mm 3 x M20 (Pg 13.5) laterally, 1 x M16 below
Flashlight
Voltage range: 9 - 60 V DC
Color of Flashlight: red
Ambient temperature: -10 °C to +55 °C
Type of protection: IP 21C
Emergency stop button
self-locking, resettable by pulling, tamper-proof according to ISO 13850/EN 418, with illuminated indicator
Type of protection: IP66/IP67
Ambient temperature: -30 °C to +70 °C
Dimensions (W x H x D): 80 x 103.9 x 72 mm 2 x M20/M25.1 x M20 (Pg 13.5) laterally, 2 x M16 below